Product Documentation

File description: MT1MADSL1A


Product file format: HDF5

Product datasets

Dataset DataType Dimensions units valid_range scale_factor add_offset _FillValue Missing_Output long_name
Beginning of group : ScienceData
IncidenceAngle_Samples_HF int8 [?,
?]
degree [51.72,54.27] 0.01 53.0 127 NONE Incidence angle of at the center of samples
IncidenceAngle_Samples_LF int8 [?,
?]
degree [51.72,54.27] 0.01 53.0 127 NONE Incidence angle at the center of samples
IncidenceAngle_Samples_MF int8 [?,
?]
degree [51.72,54.27] 0.01 53.0 127 NONE Incidence angle at the center of samples
Latitude_Nadir uint16 [?] degree [-40.0, 40.0] 0.01 -40.0 65535 NONE latitude of sub satellite point
Latitude_Samples_HF uint16 [?,
?]
degree [-40.0, 40.0] 0.01 -40.0 65535 NONE latitude of high resolution samples
Latitude_Samples_LF uint16 [?,
?]
degree [-40.0, 40.0] 0.01 -40.0 65535 NONE latitude of Low resolution (18.7 GHz, 23.8 GHz, 36.5 GHz) samples
Latitude_Samples_MF uint16 [?,
?]
degree [-40.0, 40.0] 0.01 -40.0 65535 NONE latitude of Mid resolution(89.0 GHz) samples
Longitude_Nadir uint16 [?] degree [0.0, 360.0] 0.01 0.0 65535 NONE longitude of sub satellite point
Longitude_Samples_HF uint16 [?,
?]
degree [0.0, 360.0] 0.01 0.0 65535 NONE longitude of high resolution(157GHz) samples
Longitude_Samples_LF uint16 [?,
?]
degree [0.0, 360.0] 0.01 0.0 65535 NONE longitude of low resolution(18.7GHz, 23.8GHz, 36.5GHz) samples
Longitude_Samples_MF uint16 [?,
?]
degree [0.0, 360.0] 0.01 0.0 65535 NONE longitude of mid resolution(89GHz) samples
MADRAS_QF_scan uint16 [?] NONE NONE NONE NONE NONE NONE Quality flag Applicable to the Scan Line
QF_Samples_157.0_H uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 157.0_H
QF_Samples_157.0_V uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 157.0_V
QF_Samples_18.7_H uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 18.7_H
QF_Samples_18.7_V uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 18.7_V
QF_Samples_23.8_V uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 23.8_V
QF_Samples_36.5_H uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 36.5_H
QF_Samples_36.5_V uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 36.5_V
QF_Samples_89.0_H uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 89.0_H
QF_Samples_89.0_V uint16 [?,
?]
NONE NONE NONE NONE NONE NONE Quality flag of sample for channel 89.0_V
Scan_FirstSampleAcqTime_HF string200 [?,
?]
UTC time upto microsecond level NONE NONE NONE yyyymmdd hhmmssuuuuuu NONE HF :Date and time of first sample
Scan_FirstSampleAcqTime_LF string200 [?,
?]
UTC time upto microsecond level NONE NONE NONE yyyymmdd hhmmssuuuuuu NONE LF :Date and time of first sample
Scan_FirstSampleAcqTime_MF string200 [?,
?]
UTC time upto microsecond level NONE NONE NONE yyyymmdd hhmmssuuuuuu NONE MF :Date and time of first sample
Scan_Gain float32 [?,
?]
instrumentcounts/Kelvin [5.0, 13.0] 1.0 0 3.4E38 NONE Estimated Gain
Scan_HotLoadTemperature uint16 [?] Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Hot load estimated average physical temperature
Scan_Number uint16 [?] NONE [0, 65535] NONE 000336393 65535 NONE Scan Number
Scan_Offset float32 [?,
?]
kelvin [0.0, 150.0] 1.0 0 3.4E38 NONE Estimated offset
TB_Samples_157.0_H uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 157.0_H channel
TB_Samples_157.0_V uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 157.0_V channel
TB_Samples_18.7_H uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 18.7_H channel
TB_Samples_18.7_V uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 18.7_V channel
TB_Samples_23.8_V uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 23.8_H channel
TB_Samples_36.5_H uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 36.5_H channel
TB_Samples_36.5_V uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 36.5_V channel
TB_Samples_89.0_H uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 89.0_H channel
TB_Samples_89.0_V uint16 [?,
?]
Kelvin [0.0, 400.0] 0.01 0.0 65535 NONE Sample brightness temperature of 89.0_V channel
End of group : ScienceData



Product global attributes
None

Autodpc 1.2.5 - © 2012 - ICARE Data and Services Center
 

 

back to the top

Search

Dear AERIS/ICARE Users,

a maintenance operation is scheduled from Tuesday, February 17, 2026 at 5:00 PM CEST to Thursday, February 19 in the morning.

The access to the computing cluster (ACCESS server) will be interrupted during this period.

We apologize for any inconvenience this may cause.

Best regards,

The AERIS/ICARE Team